MAIN RELAY
Fuel Injection (Fuel Systems)
4) Remove main relay from mounting bracket.
S185050
19. Main Relay
A: REMOVAL
S185050A18
for_01_22-171.jpg
1) Disconnect battery ground cable.
for_01_22-172.jpg
B: INSTALLATION
S185050A11
Install in the reverse order of removal.
2) Remove bolt which holds bracket of main relay and fuel pump relay.
for_01_22-173.jpg
3) Disconnect connectors from relays.
for_01_22-174.jpg
(A)     Blower fan motor relay
(B)     Main relay
(C)    Fuel pump relay
FU(DOHC TURBO)-48