CLEAR MEMORY MODE
Engine (Diagnostics)
13. Clear Memory Mode
S058513
3. OBD-II GENERAL SCAN TOOL
S058513A1603
A: OPERATION
S058513A16
For clear memory procedures using the OBD-II general scan tool, refer to the OBD-II General Scan Tool Instruction Manual. After the memory has been cleared, the idle air control solenoid valve must be initialized. To do this, turn the ignition switch to the ON position. Wait 3 seconds before starting the engine.
1.  SUBARU SELECT MONITOR (NORMAL
MODE) S058513A1601
1)  On the <§Main Menu> display screen, select the {2. Each System Check} and press the [YES] key.
2)  On the ^System Selection Menu> display screen, select the {Engine Control System} and press the [YES] key.
3)   Press the [YES] key after displayed the infor­mation of engine type.
4)  On the ^Engine Diagnosis^ display screen, select the {Clear Memory} and press the [YES] key.
5)  When the 'Done' and Turn Ignition Switch OFF' are shown on the display screen, turn the Subaru Select Monitor and ignition switch to OFF.
NOTE:
-  After the memory has been cleared, the idle air control solenoid valve must be initialized. To do this, turn the ignition switch to the ON position. Wait 3 seconds before starting the engine.
-   For detailed operation procedure, refer to the SUBARU SELECT MONITOR OPERATION MANUAL.
2.   SUBARU SELECT MONITOR (OBD
MODE) S058513A1602
1)  On the <§Main Menu> display screen, select the {2. Each System Check} and press the [YES] key.
2)  On the ^System Selection Menu> display screen, select the {Engine Control System} and press the [YES] key.
3)   Press the [YES] key after displayed the infor­mation of engine type.
4)  On the ^Engine Diagnosis^ display screen, select the {OBD System} and press the [YES] key.
5)  On the <§OBD Menu> display screen, select the {4. Diagnosis Code(s) Cleared} and press the [YES] key.
6)  When the 'Clear Diagnostic Code?' is shown on the display screen, press the [YES] key.
7)  Turn Subaru Select Monitor and ignition switch to OFF.
NOTE:
-  After the memory has been cleared, the idle air control solenoid valve must be initialized. To do this, turn the ignition switch to the ON position. Wait 3 seconds before starting the engine.
-   For detailed operation procedure, refer to the SUBARU SELECT MONITOR OPERATION MANUAL.
EN(SOHC)-45