17. Main Relay

S155050

A: REMOVAL

S155050A18

1) Disconnect battery ground cable.

for_01-299.jpg

2) Remove bolt which holds bracket of main relay and fuel pump relay.

for_01-301.jpg

3) Disconnect connectors from relays.

for_01-302.jpg

4) Remove main relay from mounting bracket.

for_01-300.jpg

(A)     Blower fan motor relay

(B)     Main relay

(C)    Fuel pump relay

B: INSTALLATION

S155050A11

Install in the reverse order of removal.