17. Main Relay
S155050
A: REMOVAL
S155050A18
1) Disconnect battery ground cable.
2) Remove bolt which holds bracket of main relay and fuel pump relay.
3) Disconnect connectors from relays.
4) Remove main relay from mounting bracket.
(A) Blower fan motor relay
(B) Main relay
(C) Fuel pump relay
B: INSTALLATION
S155050A11
Install in the reverse order of removal.