6. Drive Belt(s)

SA07684

A: INSPECTION

SA07684A10

1)   Replace belts, if cracks, fraying or wear is found.

2)  Check drive belt tension and adjust it if necessary by changing generator installing position and/or idler pulley installing position.

Belt tension (A)

replaced: 7-9 mm (0.276 - 0.354 in)

reused: 9.0 - 10.0 mm (0.354 - 0.394 in) (B)*

replaced: 7.5 - 8.5 mm (0.295 - 0.335

in)

reused: 9.0 - 10.0 mm (0.354 - 0.394 in)

*: There is no belt (B) on models without an air conditioner.

for_01-48.jpg

C/P Crankshaft pulley

GEN Generator

P/S Power steering oil pump pulley

A/C Air conditioning compressor pulley

I/P Idler pulley

B: REPLACEMENT

SA07684A20

NOTE:

Wipe off any oil or water on the belt and pulley.

1)   Loosen the lock bolt (A).

2)   Loosen the slider bolt (B).

3)   Remove the front side belt (C).

for_01-49.jpg

4)   Loosen the lock nut (A).

5)   Loosen the slider bolt (B).

6)   Remove the rear side belt.

for_01-50.jpg

7)   Install a new belt, and tighten the slider bolt so as to obtain the specified belt tension.

8)  Tighten the slider bolt (B).

9)  Tighten the lock nut (A).

Tightening torque:

22.6 Nm (2.3 kgf-m, 16.6 ft-lb)

for_01-51.jpg

10)   Install a new belt, and tighten the slider bolt so as to obtain the specified belt tension.

11)  Tighten the slider bolt (B).

12)  Tighten the lock bolt (A).

Tightening torque: Lock bolt, through bolt:

25 Nm (2.5 kgf-m, 18 ft-lb) Slider bolt:

8 Nm (0.8 kgf-m, 5.8 ft-lb)

for_01-52.jpg