FUEL CUT VALVE
|
||||
|
||||
Fuel Injection (Fuel Systems)
|
||||
|
||||
26. Fuel Cut Valve
|
S155021
|
|||
|
||||
A: REMOVAL
|
S155021A18
|
|||
|
||||
|
||||
WARNING:
- Place "NO FIRE" signs near the working area.
- Be careful not to spill fuel on the floor.
1) Remove fuel tank. <Ref. to FU(SOHC)-55, REMOVAL, Fuel Tank.>
2) Move clip and disconnect evaporation hose from fuel cut valve.
|
||||
|
||||
![]() |
||||
|
||||
3) Remove bolts which install fuel cut valve.
B: INSTALLATION S155021A11
Install in the reverse order of removal.
Tightening torque:
4.4 Nm (0.45 kgf-m, 3.3 ft-lb)
|
||||
|
||||
![]() |
||||
|
||||
FU(SOHC)-67
|
||||
|
||||