FRONT OXYGEN (A/F) SENSOR
|
Fuel Injection (Fuel Systems)
|
||||
|
|||||
14. Front Oxygen (A/F) Sensor
|
B: INSTALLATION
1) Before installing front oxygen (A/F) sensor, apply anti-seize compound only to threaded porÂtion of front oxygen (A/F) sensor to make the next removal easier.
Anti-seize compound: SS-30 by JET LUBE
CAUTION:
Never apply anti-seize compound to protector
of front oxygen (A/F) sensor.
|
||||
S155642
|
|||||
|
|||||
A: REMOVAL
|
S155642A18
|
||||
1) Disconnect battery ground cable.
|
|||||
![]() |
|||||
![]() |
|||||
2) Disconnect connector from front oxygen (A/F) sensor.
|
|||||
![]() |
|||||
2) Install front oxygen (A/F) sensor.
Tightening torque:
21 Nm (2.1 kgf-m, 15.2 ft-lb)
|
|||||
![]() |
|||||
3) Lift-up the vehicle.
4) Apply SUBARU CRC or its equivalent to threaded portion of front oxygen (A/F) sensor, and leave it for one minute or more.
SUBARU CRC (Part No. 004301003)
5) Remove front oxygen (A/F) sensor.
CAUTION:
When removing the oxygen (A/F) sensor, wait until exhaust pipe cools, otherwise it will damÂage exhaust pipe.
|
|||||
3) Lower the vehicle.
4) Connect connector of front oxygen (A/F) senÂsor.
|
|||||
![]() |
|||||
![]() |
|||||
|
|||||
FU(SOHC)-45
|
|||||
|
|||||